Jun 172010
 

Architect – Skye Homes

Mechanical Contractor – Anderson Floor Warming

Air Source Heat Pump

Anderson Floor Warming designed, supplied and installed a Nibe ‘Fighter’ 2005 8kW Air Source Heat Pump linked via our joint free pre-insulated PEX heating primary system to the underfloor heating system, utilising pipe in staple in a screeded floor. Radiators supply heat to the first floor with towel rails in the bathrooms on each floor.

underfloor heating layout

Pre-insulated joint free PEX pipe hot and cold primary system distributes the pressurised hot and cold water to the secondary manifolds throughout the property.

Air Source Heat Pump