Mar 172014
 

Architect – Cooper Cromar

Main Contractor – Speyroc Construction Ltd

underfloor heating

Located in the 61 acre West of Scotland Science Park, the Altum Building is an energy efficient, two storey pavilion housing 16,800ft² of high quality office accommodation.

underfloor heating

Anderson Floor Warming And Renewables were responsible for the design, supply and installation of the underfloor heating system including insulation and screed. Above you can see the insulation being laid.

underfloor heating

This is followed by a layer of visqueen.

underfloor heating

The underfloor heating pipe is then laid on top. This project uses the pipe in staple system.

underfloor heating

Finally, a screed finish is poured, covering the pipes and acting as a thermal mass for the heating system.

underfloor heating

A completed floor ready for a suitable finish to be laid for the occupants of the building.